The application of anticorrosive and marine coatings are extremely varied. From public works to civil engineering, from ships to the mining sector, Corrosion Control System (CCS) has been intervening as an expert since its creation in 2007.
Our inspectors are ACQPA-FROSIO and NACE certified.



CCS supports you in:
1
Technical assistance for project management:
• Expertise, Inspections and Diagnostics of engineering structures.
• Technical assistance during the design and construction phase.
• Advice on procedures and paint coating systems and technical recommendations.
• Lead (Pb) detection and Audits (2022 project).
• Cathodic protection study and audits (periodic inspection).
2
External control
• External QAQC on painting and assembly of metal structures
• Certification of validity and conformity of documents (PAQ, ITP etc.)
• Continuous monitoring of painting work (destructive or non-destructive testing) “in situ” and investigation.
• Certification of conformity of ongoing work.
• Our inspectors are ACQPA-FROSIO certified: #3631, #3553, #10619
• And we have one NACE inspector: CIP L2 #80263
Areas of activity:
• Engineering Structures (bridges, footbridges, maritime structures, etc.)
• Port infrastructure and tools
• Industrial facilities
• Public buildings
• All metallic structures
Example of normative standards
- NF EN ISO 12 944: Paints and varnishes - Anticorrosion of steel structures by painting systems
- NF EN ISO 19 840: Paints and varnishes. Anticorrosion of steel structures by painting systems. Measurement and acceptance criteria for the thickness of a dry film.
- NF EN ISO 8501: Visual assessment of the cleanliness of a surface.
- NF EN ISO 8503: Roughness characteristic
- NF EN ISO 4624: Paints and varnishes – Tensile test.
- NF EN ISO 4628: Assessment of the degradation of painted surfaces. Designation of the intensity, quantity and size of common types of defects.
- Fascicle 56 - french specification applicable to public works contracts (Protection of metal works against corrosion)
- NS 476: Certification of ACQPA-FROSIO Inspectors
Control equipment
- Surface profile test
- Viso-tactile comparator PIG test, paint coating thickness test
- Magnetic thickness gauge (metallic and non-metallic)
- Test to detect the presence of soluble salts
- Chloride, Sulfate and Nitrate ion detection test
- Hygrometer
- Porosity/Pinholes detector
- Adhesion test through destructive method (pulloff and crosscut test)
- Kit for determining chloride ion in abrasive materials